Class 100 Vertical Air Flow Clean Bench

Class 100 Vertical Air Flow Clean Bench

1,Professional, technical light suouce design. If the source is not designed properly operatorwill get tired quickly. 2, The super clean bench are striclty tested before they leave the factory to ensure normal use. 3, There are two type of air circulation: open loop and claose loop Open loop air...

InquiryChat Now

  • Product Details

1,Professional, technical light source design.   If the source is not designed properly operator will get tired quickly.

2, The super clean bench are striclty tested before they leave the factory  to ensure normal use.

3, There are two type of air circulation: horizontal open loop and  vertical close loop

  • Open loop air circirculation is as follows , the main feature is that in each cycle all the air is collected from the outside through clean bench box and returned to the atmosphere directly. The general horizontal flow superclean working table adopts the opening loop, this kind of clean bench  structure is simple, cost is low, but the fan and filter load is heavily, it has a bad effct on its using life, at the same time the cleaning efficiency of fullly open air circulation is not high, ususally only for low cleanliness requirements or biological hazzrds environment . 

  • The closed loop is not actually a complete inner air flow cycle. Air will be discharged into the atmosphere in each cycle,aAfter passing through the working area, 70% of the gas passes through the orifice and enters the nest cycle again. Compared to the outside air, the gas is still relatively pure, so the filter load is lighter , services life will also be longer, and this air circulation is adopted by the current main clean bench product.

4, The vertical ultra clean bench install ultraviolet lamp for disinfection and sterillization.

UV ligh j.jpg

In fact, we suggest that the replacement cycle of the primary filter is based on eight hours per day, there for ,if individual customers use time is relatively less, do not know when to replace the ffilter, we could install a presure difference gauge. The filter should be replaced when the resistance is close to 500PA

utility_pressure_gauge.jpg


Features:


  • The 1.5 thick high quality cold rolled steel plate by electrostatic spraying  treatment(or stainless steel)

  • Stainless steel work table

  • High quality centrifugal fan

  • American Dwyer differential pressure gauge. 

  • Pre- HEPA two stage filtration, easy to operate, equiped with universal wheel, can move every directions

  • A variety of moddels can be customeized according to the actual needs of customers


3.jpg

Operation and maintenance proceduare:

1 Oprating procedures: 

(1) Turn the machine 50 minutes in advance when using the work bench,  ture on the lamp at the same time,  treatment of microorganisms accumulated on the surface of opration area, ture off the germicidal lamp after 30 minutes(when the fluorescent lamp is on) , start the fan .


(2) for newly installed or long-term unused workstaions, it is neecessary to clean the table and surrounding environment with a super -static vacuum cleaner of with tools that do not produce fiber before using, the UV methord was used for further treatment.


How to select a clean bench:

You must pay attention to super clean bench fan (blower )and filter! these two things show the level of product technology, can't be faked, we use EBM fan.


HEPA filter.png

Laboratory biological photoelectric industry microelectronic/ hard disk manufacturing and other fields.


Vertical:

 

Model

AL-VC-1000

AL-VC-1200

AL-VC-1500

AL-VC-1800

External Size (mm)

W1000×D700×H1800

W1200×D700×H1800

W1500×D700×H1800

W1800×D700×H1800

Internal Size (mm)

W900×D650×H600

W1100×D650×H600

W1400×D650×H600

W1700×D650×H600

Table Height(mm)

750

750

750

750

Clean Class Level

100Class 0.3µm(ISO14644-1 International Standard)

Rated Air Flow

900m3/h

1200m3/h

1500m3/h

1800m3/h

Air Velocity

0.3-0.6m/s

0.3-0.6m/s

0.3-0.6m/s

0.3-0.6m/s

HEPA Efficiency

99.99% 0.3µm above (H13-H14)

Vibration Half Peak

damping separate countertops ( optional )

Noise

≤50dB

≤50dB

≤50dB

≤50dB

Material

Cabinet: epoxy powder coated steel or stainless steel, Table-board: stainless steel

Illumination

≥300lux

≥300lux

≥300lux

≥300lux

LED light

9W×1

13W×1

18W×1

24W×1

Power

124W

127W

200W

248W

Noise

≤50dB

≤50dB

≤50dB

≤50dB

Power Supply

220V/50Hz

220V/50Hz

220V/50Hz

220V/50Hz

Suitable Person

1

1-2

2-3

3-4


Hot Tags: class 100 vertical air flow clean bench, manufacturers, suppliers, factory, wholesale